- Home Page /
- Automotive /
- Automotive Replacement Parts /
- Lighting & Electrical /
- Electrical /
- Gauges /
- Gauge Sets /
- 57302 Temperature Switch Gauge 4 ft Capillary
57302 Temperature Switch Gauge 4 ft Capillary
MVR 2540
Price Details
Excluding Shipping & Custom charges ( Shipping and custom charges will be calculated on checkout )
*All items will import from US
QTY:
Ubuy works hard to protect your security and privacy. Our advanced payment security system ensures confidentiality by encrypting your information during transmission using AES (Advanced Encryption Standards) and SSL (Secure Socket Layer) protocols. Your payment details are 100% secure as we do not share your payment details with third party sellers.
52mm Mechanical gauge with Chrome Bezel and Black dial, Range 40 -120C
Fast
Shipping
Free
Return*
Secure Packaging
100% Original Products
PCI DSS Compliance
ISO 27001 Certified
What Stands Out
Product Details
- This is a 52mm mechanical gauge, perimeter-lit, with chrome bezel and black dial. Range 40 -120c, capillary length - 4 feet, end fitment- 5/8"-18 unf with 1/2" adapter.
- This gauge has a built-in electrical switch for tripping alarms and/or shutdown devices.
- this gauge has a sealed capillary tube and a sensing bulb. When subjected to heat, the liquid in the sensing bulb changes to vapor creating pressure which translates this vapor pressure into a mechanical gauge reading.
- The gauge pointer acts as a temperature indicator and as a one switch pole which completes a circuit when it touches the adjustable limit contact. The preset level can be changed using a 1.6mm allen key.
- All local taxes and import levies - sales tax, GST, VAT, Custom duties, etc will have to be paid by the customer.
| Brand Name | Veethree |
| Manufacturer | Indication Instruments Ltd |
| Unit Count | 1 Count |
| Item Weight | 1 Kilograms |
| Material Type | Glass, Metal |
| Brand | Veethree |
| Material | Glass, Metal |
Who Should Buy?
-
HVAC Technicians
Ideal for HVAC professionals needing precise temperature monitoring in residential or commercial heating systems.
-
Industrial Applications
Suitable for industrial settings requiring robust temperature monitoring for machinery and processing equipment.
-
DIY Enthusiasts
Great for hobbyists and DIYers working on temperature-sensitive projects or appliance repairs.
-
High Precision Labs
Not suited for laboratories demanding high accuracy or specialized temperature measurement beyond standard applications.
-
Non-Technical Users
May be challenging for users without technical expertise or experience in installation and calibration.
-
Extreme Environments
Not ideal for extremely high-pressure or corrosive environments where specialized gauges are required.
Product Description
Customer Questions & Answers
-
Question:
What is the 57302 Temperature Switch Gauge 4 ft Capillary used for?
Answer: The 57302 Temperature Switch Gauge 4 ft Capillary is primarily used to monitor temperature levels in various industrial and commercial applications. It operates by using a capillary tube to measure the temperature of fluids or gases, sending the data to a gauge for easy reading. This is particularly useful in HVAC systems, refrigeration units, and industrial processes where precise temperature regulation is crucial. -
Question:
How does the capillary tube in the temperature switch work?
Answer: The capillary tube in the 57302 Temperature Switch Gauge works by expanding or contracting with temperature changes. When the temperature rises, the liquid inside the tube expands, which pushes a mechanism that indicates the temperature on the gauge. This design allows for accurate and responsive readings, making it ideal for environments that require constant temperature monitoring. -
Question:
Is the 57302 Temperature Switch Gauge suitable for outdoor use?
Answer: Yes, the 57302 Temperature Switch Gauge is suitable for outdoor use, but its longevity can depend on the specific environmental conditions. The gauge's construction often includes materials resistant to corrosion and other outdoor elements. This makes it ideal for applications like outdoor HVAC units or greenhouse climate control, where outdoor temperature variations are a factor. -
Question:
What is the proper installation procedure for the 57302 Temperature Switch Gauge?
Answer: Proper installation of the 57302 Temperature Switch Gauge involves securely attaching the gauge to the appropriate surface and connecting the capillary tube to the area being monitored. It's essential to ensure there are no kinks in the capillary tube to maintain accuracy. This gauge is commonly used in situations like mechanical rooms or industrial equipment where precise temperature readings are needed for efficiency. -
Question:
Can the 57302 Temperature Switch Gauge be calibrated?
Answer: Yes, calibration of the 57302 Temperature Switch Gauge is possible and recommended to ensure accurate readings. Calibration can typically be accomplished by comparing the gauge readings with a known temperature source and making adjustments as necessary. Regular calibration is crucial, especially in applications such as food processing or laboratory environments, where precise temperature control is essential. -
Question:
What are the key features of the 57302 Temperature Switch Gauge?
Answer: The key features of the 57302 Temperature Switch Gauge include a 4-foot capillary tube for versatile installation, a robust construction for durability, and a clear, easy-to-read display. These features make it suitable for various applications, such as monitoring temperatures in industrial machinery or HVAC systems, allowing users to easily assess the operational state of their equipment. -
Question:
What type of fluids can the temperature switch gauge monitor?
Answer: The 57302 Temperature Switch Gauge can monitor a variety of fluids including water, oil, and refrigerants. The gauge's design is compatible with numerous fluids commonly used in industrial and commercial applications, enabling it to be a versatile tool. For instance, it can be found in HVAC systems regulating refrigerant temperatures or in engines monitoring oil temperatures, helping maintain optimal functioning. -
Question:
What maintenance is required for the 57302 Temperature Switch Gauge?
Answer: Maintenance of the 57302 Temperature Switch Gauge is relatively straightforward. Regular checks should be made to ensure the gauge is clean and unobstructed for accurate readings. It's also wise to inspect the capillary tube for any signs of wear or damage. This level of maintenance is essential to ensure reliable performance in applications like industrial processing or climate control systems. -
Question:
What are the advantages of using a temperature switch gauge like the 57302?
Answer: Using a temperature switch gauge like the 57302 provides numerous advantages, including reliable temperature monitoring, durability, and the ability to promptly respond to temperature changes. Its capillary design ensures quick and accurate readings, making it a great choice for critical systems where temperature control is vital. This is generally helpful in environments like manufacturing plants, where monitoring can prevent equipment failures. -
Question:
Where can I buy the 57302 Temperature Switch Gauge 4 ft Capillary?
Answer: You can purchase the 57302 Temperature Switch Gauge 4 ft Capillary from Ubuy, which is a reputable online shopping platform in Maldives. Ubuy offers a wide selection of products and ensures a smooth shopping experience, making it easier for you to find and acquire the necessary equipment for your temperature monitoring needs.
Veethree Gauge Sets Editorial Review
Customer Reviews & Ratings
-
5 Star
100%
-
4 Star
0%
-
3 Star
0%
-
2 Star
0%
-
1 Star
0%
Review this product
Share your thoughts with other customers
Pros
- High accuracy temperature readings
- Durable and weather-resistant design
- Easy installation with 4 ft capillary
- Quick response time
- Wide range of temperature measurement
Cons
- Occasional calibration needed
Product Price History
Important information
- Limitations : For products shipped internationally, please note that any manufacturer warranty may not be valid; manufacturer service options may not be available; product manuals, instructions, and safety warnings may not be in destination country languages; the products (and accompanying materials) may not be designed in accordance with destination country standards, specifications, and labeling requirements; and the products may not conform to destination country voltage and other electrical standards (requiring use of an adapter or converter if appropriate). The recipient is responsible for assuring that the product can be lawfully imported to the destination country. When ordering from Ubuy or its affiliates, the recipient is the importer of record and must comply with all laws and regulations of the destination country.
- Not all the products listed on Ubuy are for sale, as Ubuy is a global search engine. Products are subject to export/trade regulations.
MVR 2540
Order now and get it around Friday, August 07
This item is not restrict in my country.(Please click on above link if this item is not restrict in your country, So our team will review and allow.)
QTY:
Ubuy works hard to protect your security and privacy. Our advanced payment security system ensures confidentiality by encrypting your information during transmission using AES (Advanced Encryption Standards) and SSL (Secure Socket Layer) protocols. Your payment details are 100% secure as we do not share your payment details with third party sellers.
Features & Benefits
- Has a built-in electrical switch for tripping alarms and/or shutdown devices
- Sealed capillary tube and a sensing bulb for more accurate readings
- Gauge pointer acts as a temperature indicator and as a one switch pole
- Preset limit can be easily changed using a 1.6mm allen key
- Perimeter-lit for easy reading in low light conditions
- Comes with 4 feet capillary length and 5/8-18 UNF with 1/2 Adapter